APPLICATION
Application Note
*Optimal dilutions/concentrations should be determined by the researcher.
Application |
Recommended Dilution |
Assay dependent |
Not tested in other applications.
Calculated MW
Product Note
This antibody binds the free N-terminus of GLP-1(7-37) and GLP-1(7-36)amide and shows <0.2% cross-reactivity with GLP-1(9-36)amide, glucagon and human GIP. Cross-reacts 0.25% with GLP-1(1-37), approximately 6% with human GLP-2 and approximately 50% with exendin-4. this antibody cross-reacts with Liraglutide.
PROPERTIES
Form
Liquid
Buffer
0.01M Phosphate buffer pH7.4, 0.14M NaCl
Preservative
15mM Sodium azide
Storage
Store as concentrated solution. Centrifuge briefly prior to opening vial. Store at 4ºC.
Concentration
1 mg/ml (Please refer to the vial label for the specific concentration.)
Immunogen
Synthetic GLP-1(7-17)
Purification
Biotinylated
Conjugation
Biotin
Note
For laboratory research use only. Not for any clinical, therapeutic, or diagnostic use in humans or animals. Not for animal or human consumption.
Purchasers shall not, and agree not to enable third parties to, analyze, copy, reverse engineer or otherwise attempt to determine the structure or sequence of the product.
TARGET
Synonyms
glucagon , GLP-1 , GLP1 , GLP2 , GRPP
Cellular Localization
Secreted
Background
The protein encoded by this gene is actually a preproprotein that is cleaved into four distinct mature peptides. One of these, glucagon, is a pancreatic hormone that counteracts the glucose-lowering action of insulin by stimulating glycogenolysis and gluconeogenesis. Glucagon is a ligand for a specific G-protein linked receptor whose signalling pathway controls cell proliferation. Two of the other peptides are secreted from gut endocrine cells and promote nutrient absorption through distinct mechanisms. Finally, the fourth peptide is similar to glicentin, an active enteroglucagon. [provided by RefSeq, Jul 2008]
Database
Research Area
DATA IMAGES
|
GTX60952-02 ELISA Image
The calibration curve of a sandwich assay for Non-amidated GLP-1 using GTX60954 as the capture antibody and GTX60952 -02 as the biotinylated detection antibody.
|
|
GTX60952-02 ELISA Image
This uses GTX60951 as capture antibody in combination with biotinylated detection antibody GTX60952 -02 exclusively to measure GLP-1(7-36)amide in biological samples. GLP-1(7-36)amide is the principal active form of the peptide, and has been estimated to make up about 70% of the physiological response. Relative to measuring both active forms of GLP-1 together, the responses are reduced by not measuring the approximately 30% contribution of GLP-1(7-37) to the overall response. There is no cross-reactivity with any extended or truncated physiological form of GLP-1(7-36)amide. Specimens must be collected into tubes containing an adequate amount of DPP-4 inhibitor (in addition to routine peptidase inhibitors) to prevent the rapid in vitro degradation of the active peptide.
|
REFERENCE
There are currently no references for GLP1 antibody [10] (Biotin) (GTX60952-02). Be the first to share your publications with this product.
REVIEW
There are currently no reviews for GLP1 antibody [10] (Biotin) (GTX60952-02). Be the first to share your experience with this product.